1) Connect positive (+) wire from MAGNETIC LOCK with any of the two wires from the surface mount ON/OFF SWITCH.
2) The remaining wire from the surface mount ON/OFF SWITCH must be connected to the positive (+) wire from the POWER SUPPLY, identified with white stripes.
3) SPECIAL NOTE: the plug head connector may have to be stripped for proper wire connections.
4) Connect negative (-) wire, identified in solid black from the POWER SUPPLY, to the COM screw on the surface mounted INTERIOR ACCESS PUSH BUTTON, then connect wire from NC screw to negative (-) wire on the MAGNETIC LOCK. To add additional INTERIOR ACCESS PUSH BUTTONS; connect wire from NC of button A to NC of button B and from NC to NC of button C (This step can be duplicated for each INTERIOR ACCESS PUSH BUTTON needed.) and from COMM. of button C (or last button in circuit) to negative (-) of Magnetic Lock.
5) Connect wire from NO screw on surface mounted INTERIOR PUSH BUTTON, to negative (-) wire, identified in solid black on EXTERIOR ELECTRONIC BUZZER.
6) Connect positive (+) wire, identified in solid red, on EXTERIOR ELECTRONIC BUZZER, to positive (+) wire on MAGNETIC LOCK.
7) For INTERIOR ELECTRONIC BUZZER connect positive (+) wire, identified solid red, to positive (+) wire, identified with white stripes, on POWER SUPPLY.
8) Finally, connect negative (-) wire from POWER SUPPLY, identified in solid black, to COM screw on surface mounted EXTERIOR PUSH BUTTON, and then connect wire from NC screw to negative (-) wire, identified in solid black on surface mounted EXTERIOR PUSH BUTTON.
*9) TO AVOID POTENCIAL ACCIDENTAL LOCK-OUTS, DO NOT INSTALL AN INTERIOR PUSH BUTTON THAT IS ACCESSABLE AT THE EXIT DOOR!!! IF YOU DO, THEN YOU MUST INSTALL A MOMENTARY OFF KEYED CAM LOCK OR AN ELECTRONIC ACCESS KEY PAD ON THE EXTERIOR OF THE EXIT DOOR.